Observation Bit: Commissioning 16:07 Realign after Lockloss 18:10 Dick G. - Going into Optics Lab 19:20 Dick G. – Out of Optics Lab 20:10 IFO locked at LSC_FF 20:15 Observation bit set to Undisturbed 20:36 Lockloss Reason unknown 21:45 IFO locked at LSC_FF 21:50 Observation bit set to Undisturbed 22:03 Adjust ISS diffracted power from 12% to 8% 22:17 Lockloss – Reason unknown 22:21 Re-Start initial alignment after Lockloss 22:40 Complete initial alignment 22:43 Start Guardian locking 23:14 Lockloss – restart locking process 23:55 Lockloss at Engage_ASC 00:00 Due to problems locking left IFO in a down state. Very difficult to do initial alignment and to get the IFO to lock. There was a large amount of activity in the 1 -3Hz and 3 - 10Hz seismic ranges and several periods of higher winds (upper 30 mph and mid 20 mph). Large ring up in Bounce and Roll modes each time reached Engage_ASC stage. Limited success in suppressing these.