Reports until 15:57, Monday 01 June 2015
H1 CAL
jeffrey.kissel@LIGO.ORG - posted 15:57, Monday 01 June 2015 (18755)
:2000 FM3 filter turned OFF for ANALOG_ETMX_L3 BANK in CAL-CS
J. Kissel, K. Izumi

While we were showing Sudarshan some things, we recalled that FM3 of the 
H1:CAL-CS_DARM_ANALOG_ETMX_L3
bank included a filter to compensate the 2e3 pole for the high voltage ESD driver. Since we'll be using ETMY for the engineering run, which has a new low noise driver without this pole, we have turned this filter off.

First update to the CAL-CS calibration for ER7 woo!

This change was seen by the SDF system, and I've accepted the change.