[Ryan F, Duncan M, etc.]
I have committed a new version of the CAL_INJ_MASTER common library model used to control hardware injections in the front-end system. This change reimplements the logic for the ODC state vector, making the state reporting more robust, and implementing logging for the Stochastic injections. The change has no impact outside of the /INJ/ODC block excepting input connections to that block.
If this model could be pulled onto the production system at LHO, and the h1calcs front-end rebuilt and restarted, that would be spiffing. At LLO this change did not require a restart of daqd, which is nice.
Once that change is made, I can remotely modify the related MEDM screens and EPICS variables to ensure that hwinj reporting is configured correctly before data-taking restarts this afternoon.