Reports until 11:52, Tuesday 02 June 2015
H1 CAL (CDS, DAQ)
david.barker@LIGO.ORG - posted 11:52, Tuesday 02 June 2015 - last comment - 12:21, Tuesday 02 June 2015(18780)
MC2 M3 DAC recalibrated

Jeff, Dave

We restarted the h1iopsush34 model, which performed a calibration on all six 18bit DAC cards (including MC2's M3 DAC which had reported zero crossing glitching Link). All autocals completed successfully. 

Andrew, could you verify if the recalibration has made any improvement in MC2 M3? The calibration could deteriorate over time.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:21, Tuesday 02 June 2015 (18786)CDS, DetChar, SUS
For the record, my LHO aLOG 18783 is documenting the same as this above entry. Sorry for the repeat logging!