Reports until 14:16, Tuesday 02 June 2015
X1 DTS (CDS)
james.batch@LIGO.ORG - posted 14:16, Tuesday 02 June 2015 (18792)
Connect multimode fiber between DAQ test stand and Computer User Room
WP 5219

Pulled excess multimode fiber cable from computer user's room (CUR) to MSR to allow them to be connected to the patch panel in the MSR. The fibers had previously been pulled but did not reach as far as the patch panel, with the excess being coiled up in the CUR.

Connected DAQ test stand network switch to MSR using multimode fiber, then to CUR to extend the DTS network allowing a DTS workstation to be used in the CUR.  Also pulled one multimode fiber between the CUR and the timing master fanout rack to allow extending timing to the EE shop for timing component testing. Note that this fiber will not be connected to the master fanout until it is needed.