Displaying report 1-1 of 1.
Reports until 15:53, Wednesday 03 June 2015
H1 INJ (INJ)
eric.thrane@LIGO.ORG - posted 15:53, Wednesday 03 June 2015 (18831)
CW injections restarted + CW injection procedure
Jeff, Corey, Betsy, Dave, Keith, Eric

Betsy:
After the reboots yesterday, it appears that the CW hardware injections have not been restarted.
1) Can you please restart them?
2) There is no indication that this injection is OFF when looking at the CAL_INJ_CONTROL.adl.  Dave B simply noticed that there was no longer an EXC showing on his CDS overview screen.

Eric:
I just restarted the injections at LHO (at GPS=1117406895). Here are the instructions:

log on to the h1hwinj
cd /data/scirun/O1/HardwareInjection/Details
bin/start_psinject
You will be prompted to give your name and your reason for starting the injections, which are saved to the psinject log. Injections begin 60s after you hit enter.

I'll add these instructions to the DCC document.
Displaying report 1-1 of 1.