Displaying report 1-1 of 1.
Reports until 16:20, Wednesday 03 June 2015
H1 ISC
eleanor.king@LIGO.ORG - posted 16:20, Wednesday 03 June 2015 - last comment - 18:06, Wednesday 03 June 2015(18833)
PRM, SRM offloading to M1

Sheila, Elli

This morning we added filters to H1:SUS-PRM_M1_LOCK_L and H1:SUS-SRM_M1_LOCK_L to be used for offloading the M2_LOCK stage.  The motivation for this was because last night the M2 coil drivers were approaching saturation, and also to see if this might addressf the 2^16 (alog18815).  The new filters are zp0.01:0 in FM1, zp0:0.01 in FM2, and -90dB gain in FM3 and they are engaged with a gain of -0.2.  The filters are turned on by the ISC_DRMI guardian at OFFLOAD_DRMI.  We were having trouble locking this afternoon so we turned off these filters for a while, but they are back on again now as they didn't seem to be causing the locking difficulties.

Comments related to this report
sheila.dwyer@LIGO.ORG - 18:06, Wednesday 03 June 2015 (18838)

Plot of M2 master outs over last night's lock

Images attached to this comment
Displaying report 1-1 of 1.