david.barker@LIGO.ORG - posted 12:25, Friday 05 June 2015 - last comment - 12:54, Friday 05 June 2015(18898)
some LHO DMT monitors are not running

Some LHO DMT monitors are not running. John and Maddie have been emailed about the problem. There is no CAL SENSEMON or SEIS BLRMS data at the moment from H1.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 12:54, Friday 05 June 2015 (18902)DAQ

Looks like the DAQ broadcaster has stopped sending data. Its EPICS IOC is still running, but the EPICS values are frozen. There are no recent logs in the log files. We have not seen this failure before. CPU and MEM looks good on the machine.

We should discuss restarting the broadcaster (will not affect the rest of the DAQ)

Displaying report 1-1 of 1.