Displaying report 1-1 of 1.
Reports until 15:17, Friday 05 June 2015
H1 GRD
cheryl.vorvick@LIGO.ORG - posted 15:17, Friday 05 June 2015 - last comment - 15:28, Friday 05 June 2015(18908)
SDF cleared - currently all green while the IFO is in a 17.7W lock

With help from Betsy and Corey, and confirmation from Kiwamu and Hugh's alog, I cleared the IMC-DOF offsets - confirmed as a change from Robert's work and working well.

I also turned the OMC-ASC_DITHER_MASTER off.

Comments related to this report
cheryl.vorvick@LIGO.ORG - 15:28, Friday 05 June 2015 (18911)

And then again...

Actually, Dan would like the OMC Dither enabled as a monitoring point, and maybe use the dither alignment, so the agreemeet with Kiwamu and Dan was that we'd turn the dither on, and acept it in the SDF.  

OMC Dither = ON is now acepted in SDF, and SDF overview is again all green.

Displaying report 1-1 of 1.