Reports until 15:58, Sunday 07 June 2015
H1 General
cheryl.vorvick@LIGO.ORG - posted 15:58, Sunday 07 June 2015 (18961)
Ops Day Summary:

- Locked when I arrived.  Good range with some glitches until about 19UTC when braodband noise came up and reduced the range by 10-15Mpc.  

- Range did recover and then started to drop again, and then looked like it was going to recover and dropped lock.

- A blue pickup was seen on the camera about 5 minutes after lock loss - our landscapers, but not sure where they had been, only saw them head to the LSB.

- Relocking - had to start the ETMX ESD drive to lock, and then when IFO was locked again, Range was only 35Mpc.  I turned it off and Range retunrned to the level of the last lock.

- I reset all BS ISI watchdogs, and cleared the tripped watchdog on Stage 3.

- Evan returned CARM gain to a previous and higher value, and Range is just below 70Mpc.

- LLO just came back on the Range plot, and was down the last 8 hours.

- Currently: IFO locked with the Intent Bit engaged.