Displaying report 1-1 of 1.
Reports until 16:30, Sunday 07 June 2015
H1 INJ (INJ)
eric.thrane@LIGO.ORG - posted 16:30, Sunday 07 June 2015 (18962)
transient injection code tinj restarted
This report is a copy-and-paste from here: https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=18555

Peter Shawhan, Chris Pankow, Dan Hoak, Eric Thrane

Dan noticed that the transient injection script died at LHO. Peter debugged and found two errors:

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=18886
https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=18517

First, the code tinj was running out of file descriptors because of a missing fclose command, now fixed. There was also an error in the way the EPICS channel H1:CAL_TINJ_TYPE was set. It is now fixed to. Peter fixed the code in svn, but he could not recompile because of permission issues. (We are following up on that with the LHO CDS admins.) I recompiled the code at both sites and restarted the transient injection code:

GPS = 1117754506 (LHO)
GPS = 1117754609 (LLO)

There are currently no transient injections scheduled in the short-term future.
Displaying report 1-1 of 1.