Update to ESD medms

This morning there was some confusion over whether or not the EX ESD was completely off. Since the latest technique for getting some more mpc's is to turn off the EX ESD after the ifo has achieved full lock, it is important for operators to know if it is all the way off or not. After talking with Evan, he cleared up some of my confusions and this is what I've found

There are three different states that the ESD can be in:

  1. Driver ON, DC Bias ON
  2. Driver ON, DC Bias OFF
  3. Driver OFF

The confusion this morning arose from the ESD medm screen's "Active" light. The light was red but the Analog Monitors still had a few hundred counts to them. This is because the ESD DC Bias was OFF and the driver was on. To avoid this in the future, I added a third light to ESD Active. If the Active light is:

(Legend on the medm so you don't have to memorize that, screenshot attached)

Hopefully this will eliminate any future bewilderment.

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 14:23, Monday 08 June 2015 (18994)

Also, we updated the guardian to turn the EX ESD on and off as appropriate.

In LSC_FF, if the EX bias has been ramped to zero, the guardian will write 1 to H1:ISC-EXTRA_X_BO_3. This is then reset to 0 after a few seconds (by Beckhoff?). This will inactivate the driver.

In DOWN, if the analog readbacks for the driver are close to zero, the guardian will again write 1 to H1:ISC-EXTRA_X_BO_3. This is again reset to 0 after a few seconds. This activates the driver.

Occasonally it seems that the reset mechanism freezes, so that cycling BO_3 does not do anything. In this case, it usually works to do the following:

caput H1:ISC-EXTRA_X_BO_4 0

caput H1:ISC-EXTRA_X_BO_4 1

And then write 1 to H1:ISC-EXTRA_X_BO_3.