Displaying report 1-1 of 1.
Reports until 04:01, Tuesday 09 June 2015
H1 General (DetChar)
nutsinee.kijbunchoo@LIGO.ORG - posted 04:01, Tuesday 09 June 2015 - last comment - 04:56, Tuesday 09 June 2015(19004)
Lock loss 2:42 PST still trying to reacquire the lock

Jim told me that Guardian kept losing lock at BOUNCE_VIOLIN_MODE_DAMPING. After the lock loss I let Guardian took care of the locking up until this state and it lost lock as expected. I've just finish the initial alignment and will be doing the Bounce violin mode damping by hand. LOWNOISE_ESD_ETMY also known to have problems today so I will be doing the same thing when I get there. I have never run the code by hand so success not guaranteed. I'll do the best I can to get the ifo up for the 6AM hardware injection. Detcharians please stay tuned.

Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 04:56, Tuesday 09 June 2015 (19005)

04:30 Locking again at LSC_FF. Guardian worked fine when requested LOWNOISE_ESD_ETMY. Intent bit switched to undisturbed after the range is stable.