Reports until 10:32, Tuesday 09 June 2015
H1 INJ (CAL, DetChar)
jeffrey.kissel@LIGO.ORG - posted 10:32, Tuesday 09 June 2015 (19015)
Updated Hardware Injection's Inverse Actuation Filter Turned ON
J. Kissel

In the H1:CAL-INJ_HARDWARE and H1:CAL-INJ_BLIND filter banks, I've turned ON the updated inverse actuation filter for ER7 (which lives in FM2 of both banks), turned OFF the mini-run filter (which *still* lives in FM1) and accepted the changes in the SDF system. See LHO aLOG 18997 for design details of the new filter.