Reports until 13:49, Tuesday 09 June 2015
H1 AOS (AOS)
darkhan.tuyenbayev@LIGO.ORG - posted 13:49, Tuesday 09 June 2015 (19026)
Pcal line frequencies have been swapped
Sudarshan, Darkhan,

We have swapped Pcal line frequencies (EX <--> EY) and plan to keep them this way until the end of the ER7.

Before swapping we had Pcal lines at following frequencies:
PCALX at 33.1 Hz and 534.7 Hz
PCALY at 36.7 Hz and 540.7 Hz

For the rest of ER7 we will have lines at:
PCALX at 36.7 Hz and 540.7 Hz
PCALY at 33.1 Hz and 534.7 Hz

SDF_OVERVIEW monitors have been updated accordingly.