Reports until 08:32, Thursday 11 June 2015
H1 INJ (INJ)
peter.shawhan@LIGO.ORG - posted 08:32, Thursday 11 June 2015 (19068)
Ending scheduled burst hardware injections for ER7
Since we got a few coincident burst hardware injections this morning, and the rest of ER7 (now through Sunday 8:00 PDT) will be split between local measurements/commissioning and running, I have disabled the scheduled burst hardware injections for the rest of ER7.  To be precise, I left the next few dozen in the schedule but I set their amplitudes to zero, in order to test the long-term behavior and stability of tinj; tinj will call awgstream to inject them, but because awgstream will just add zero strain to the instrument, these should have no effect and will not appear in ODC bits or database segments.

There is still a plan to add a stochastic injection sometime before ER7 ends, if time permits.