Displaying report 1-1 of 1.
Reports until 00:55, Sunday 14 June 2015
LHO General
thomas.shaffer@LIGO.ORG - posted 00:55, Sunday 14 June 2015 - last comment - 15:14, Wednesday 17 June 2015(19132)
Ops Report

(times in PST)

0:04 - Locked @ LSC_FF, started PCAL swept line measurement

0:29 - PCAL measurment done, started DARM OLGTF measurement

0:50 - Both measurements done and no more for now it seems, Intention Bit set to Undisturbed

Comments related to this report
kiwamu.izumi@LIGO.ORG - 15:14, Wednesday 17 June 2015 (19200)CAL

The transfer functions that TJ measured for us have been renamed to be more obvious names as follows:

  • 2015-06-14_H1_DARM_OLGTF_LHOaLOG19132_ETMYL3LPOFF_17W.xml
  • 2015-06-14_H1PCALEY_2_DARM_LHOaLOG19132.xml

According to trend data, both mesurements seemed to have done at 17 W. The first file currently resides in aligocalibration/trunk/Runs/PreER7/H1/Measurements/DARMOLGTFs. The other one is in aligocalibration/trunk/Runs/ER7/H1/Measurements/PCAL_TRENDS.

By the way, according to what we had in the calibration svn, TJ must have accidently updated Jeff's DARM OL and Pcal Y sweep measurements with the above latest measurements. I restored Jeff's two measurements back to the previous revisions in the svn. So we now have both Jeff's and TJ's measurements checked in the SVN.

Displaying report 1-1 of 1.