edmond.merilh@LIGO.ORG - posted 10:08, Monday 15 June 2015 - last comment - 10:06, Monday 22 June 2015(19147)
NPRO Tripped again
Comments related to this report
edmond.merilh@LIGO.ORG - 10:11, Monday 15 June 2015 (19148)

I'm told this was intentional. I wasn't informed.

jason.oberling@LIGO.ORG - 14:00, Monday 15 June 2015 (19153)

This was actually completely accidental.  Peter and I went out to see if we could pull a log off of the NPRO UPS as part of our investigation into this morning's NPRO trip.  Turns out that when you plug in a DB9 cable to the back of the UPS, the UPS shuts off.  We did not know this.  Now we do.  Note to self...

In other news we were not able to establish communication between the laptop and the UPS, not sure why.  Will continue to investigate.

edmond.merilh@LIGO.ORG - 10:06, Monday 22 June 2015 (19272)

That make me feel much better about not having gone out there alone to try it!