Displaying report 1-1 of 1.
Reports until 10:26, Tuesday 16 June 2015
H1 SUS (CAL, DetChar, INJ, ISC, SEI)
jeffrey.kissel@LIGO.ORG - posted 10:26, Tuesday 16 June 2015 (19167)
ASC, LSC, SEI, SUS, OAF, and CAL-CS Front-End Model Changes This Week
J. Kissel, A. Pele,

Over the next few days, we intend to make changes to the QUAD models and the BSC-ISI models. These changes are covered in the following ECRs:

    SEI: (Work Permit: 5284)
      - Official integration of MICH Freeze infrastructure for the BSC ISI's library part.
        ECR: E1500253, 
        Int. Issue: 1063
      - Move / rename the GND STS BLRMS channels out of ST1 BSCs and up to the top-level ISI-GND block
        ECR: E1500245, 
        Int. Issue: 1059.
      - Adding Tidal correction inputs to the BSC-ISI:
        ECR: E1500270, 
        Int. Issue: 1067

    SUS: (Work Permit: 5285
      - Accomodate both observatories' versions of tidal control feedback to the QUADs:
        ECR: E1500228, 
        II: 1055
      - Reconcile LLO's QUAD top mass bounce and roll mode damping to use DARM_CTRL and any AS WFSs instead of DARM_ERR.
        ECR: E1500090, 
        II: 953
      - Modifications to the QUAD model for violin mode damping:
        ECR: E1500271,
        Int. Issue: 1067

And the following non-version controlled software will also be changed:
      - Update the corner-station LSC model to accomodate the above MICH freeze infrastructure 
        (an update to the ${userapps}/lsc/common/models/lsc.mdl, and plus new connections to IPC at the top level). 
        Work Permit: 5284
      - Update the OAF model to modify QUAD bounce and roll mode damping monitors 
        (an update to ${userapps}/isc/h1/models/h1oaf.mdl)
        Work Permit: 5278
      - Update to top-level CAL-CS model to add the blind injection channels to the frames. 
        (an update to ${userapps}/cal/h1/models/h1calcs.mdl)
        Work Permit: 5286
      - Update to the ASC model to allow for flexible choice of error signal for bounce and roll mode damping, 
        i.e. adding the WFS AS_A and AS_B YAW DOFs as possible choices 
       (an update to ${userapps}/asc/common/models/ASC_MASTER.mdl)
        Work Permit: 5278