J. Kissel, A. Pele,
Over the next few days, we intend to make changes to the QUAD models and the BSC-ISI models. These changes are covered in the following ECRs:
SEI: (Work Permit: 5284)
- Official integration of MICH Freeze infrastructure for the BSC ISI's library part.
ECR: E1500253,
Int. Issue: 1063
- Move / rename the GND STS BLRMS channels out of ST1 BSCs and up to the top-level ISI-GND block
ECR: E1500245,
Int. Issue: 1059.
- Adding Tidal correction inputs to the BSC-ISI:
ECR: E1500270,
Int. Issue: 1067
SUS: (Work Permit: 5285
- Accomodate both observatories' versions of tidal control feedback to the QUADs:
ECR: E1500228,
II: 1055
- Reconcile LLO's QUAD top mass bounce and roll mode damping to use DARM_CTRL and any AS WFSs instead of DARM_ERR.
ECR: E1500090,
II: 953
- Modifications to the QUAD model for violin mode damping:
ECR: E1500271,
Int. Issue: 1067
And the following non-version controlled software will also be changed:
- Update the corner-station LSC model to accomodate the above MICH freeze infrastructure
(an update to the ${userapps}/lsc/common/models/lsc.mdl, and plus new connections to IPC at the top level).
Work Permit: 5284
- Update the OAF model to modify QUAD bounce and roll mode damping monitors
(an update to ${userapps}/isc/h1/models/h1oaf.mdl)
Work Permit: 5278
- Update to top-level CAL-CS model to add the blind injection channels to the frames.
(an update to ${userapps}/cal/h1/models/h1calcs.mdl)
Work Permit: 5286
- Update to the ASC model to allow for flexible choice of error signal for bounce and roll mode damping,
i.e. adding the WFS AS_A and AS_B YAW DOFs as possible choices
(an update to ${userapps}/asc/common/models/ASC_MASTER.mdl)
Work Permit: 5278