PSL Status report
Laser Status: 
SysStat is good
Front End power is 33.1W (should be around 30 W); 29.1W @ Power Monitor PD
FRONTEND WATCH is GREEN
HPO WATCH is RED

PMC:
It has been locked 2 day, 21 hr 15 minutes (should be days/weeks)
Reflected power is 2.2 Watts  and PowerSum = 25.7 Watts.
(Reflected Power should be <= 10% of PowerSum)

FSS:
It has been locked for 2 d  21h and 29 min (should be days/weeks)
TPD[V] = 1.49V (min 0.9V)

ISS:
The diffracted power is around 7.2% (should be 5-9%)
Last saturation event was 2d 18 h and 5 m ago (should be days/weeks)

NOTES: ISS diffracted power was up to ~9% this morning. I've adjusted the refsignal from -2.12 to -2.14 to yield ~ 7.5%