OMC Black Glass - Update

Calum, Matt, Kate

The floors around HAM6 were so spotless you could eat off of them. Thank you Karen and Christina!!!

A 4th cleanroom was added onto the current setup, along with 2 tables. We finished rinsing the last 2 panels with methanol. Drag wiped both uncoated and coated side of each panel at least 2x, and then added hardware.

Particle counts:

  Particle Size (μm)      
  0.3 0.5 0.7 1.0 2.0 5.0 Humidity Temp Notes
1:30 PM 10 0 0 0 10 0 30% 75 F starting work
3:35 PM 30 10 0 20 0 0 35% 71 F  
4:30 PM 0 0 10 0 0 0 37% 70 F before break
5:17 PM 30 0 0 0 0 0 37% 70 F after break
6:29 PM 0 0 0 0 20 10 35% 69 F end of day