FF LSC Locklosses

This is Hannah Fair.

 

I’ve been investigating the FF LSC locklosses from ER7. The following are my findings so far.

 

About half of the FF LSC locklosses had a 20-25 second oscillation in one of the PRM and SRM channels, and in the PRCL and SRCL channels (and occasionally MICH). The start of this oscillation ranged between around -2000 seconds to only -100 seconds before lockless. All of these ended with one of the channels saturating. This saturation appears to be the cause of loss. This pattern is independent of laser power.

 

 

The following are locklosses where I also looked at OPLEV channels (Due to timing, I was unable to look at the data from the OPLEV channels for the locklosses before this):

 

 

Some of these are less detailed/precise because of timing and my inability to access data more than two weeks old.

 

Examples of this pattern are attached as images.