Displaying report 1-1 of 1.
Reports until 15:19, Thursday 09 July 2015
H1 ISC
nicolas.smith@LIGO.ORG - posted 15:19, Thursday 09 July 2015 - last comment - 14:33, Friday 10 July 2015(19531)
Sensing noise on REFLAIR 9MHz

Summary

The current of the REFLAIR diode while in lock is about a factor of 10 below where shot noise is equivalent to dark noise.

Details

In order to better understand the out-of loop behavior of the Common Mode loop, I did a lightbulb test on the REFLAIR_A diode. The thermal radiation from the lightbulb acts like a quantum limited light source at 9MHz.

lightbulb

The light was powered by a benchtop DC power supply. I mounted the bulb right in front of the diode and varied the DC light level (as seen by the REFLAIR_LF channel) and recorded the noise floor in the REFLAIR 9MHz demodulated channels. The whitening gain was temporarily changed from 12dB to 42dB for this test to overcome the ADC noise level.

The attached pdf file shows the noise vs current curve, and a fit. EDIT: apparently the LF channel is already calibrated in milliWatts. The 9MHz channel is not calibrated to physical units (though the calibration could be determined from the shot noise). As one can see, the light level we use in lock is about 10 times smaller than where shot noise starts to overcome dark noise.

REFLAIR also has an ND filter stack screwed directly on the diode box. Since we have so little light, maybe we should remove it.

Images attached to this report
Non-image files attached to this report
Comments related to this report
nicolas.smith@LIGO.ORG - 15:28, Thursday 09 July 2015 (19533)

data files

Non-image files attached to this comment
evan.hall@LIGO.ORG - 14:33, Friday 10 July 2015 (19549)

The amount of rf coming out of REFL9 in full lock (at 20+ W) is about −10 dBm, or 70 mV. It should be fine to switch over.

Images attached to this comment
Displaying report 1-1 of 1.