Reports until 00:08, Saturday 11 July 2015
H1 INS (ISC)
stefan.ballmer@LIGO.ORG - posted 00:08, Saturday 11 July 2015 (19565)
ASC stability work at 24W
Nic, Sheila, Evan, Stefan

- Turned on ITMX PIT oplev (ITMY PIT OPLEV was already on)
- DC coupled SRM PIT oplev turned on.
- Tried new SRCL input matrix YAW:
   AS 36    AI    AQ     BI    BQ         
   OLD:   -0.6   0.3    0.3   0
   NEW:    0     1.0    0     0
- This seemed better at higher power for RF offsets, but is too early for judgement.
- Also tried new SRCL input matrix PIT:
   AS 36    AI    AQ     BI    BQ         
   OLD:    0     0      2     0
   NEW:   -0.5  -0.5    0     0
- We didn't keep this one though because it seemed worse at low power.

- Attempts later tonight were hampered by winds up to 30MpH in the corner.