Kyle, Gerardo 0850 - 0900 hrs. local -> In and out of Y-end Kyle, Gerardo Connected LD to exhaust of Y-mid turbo and sprayed helium on turbo fittings -> Found that this turbo has a "Leak valve" a.k.a. a solenoid vent valve which is either not connected or absent altogether on the site's other Main Turbo Pumps (MTPs) -> The turbo had been left levitated but not spinning since John W. and Gerardo's earlier investigation -> As such, this vent valve would be open -> Found that the clamp for the blank on this valve was loose -> Tightened -> With the turbo levitated but stopped, the QDP80 running but valved-out, safety valve and turbo bypass valve opened we sprayed the turbo's CFF and NW fittings with no obvious "smoking gun" -> It is likely that tightening the blank on the vent valve may have been the leak on the turbo side of the 10" gate valve For our next session we will vent the turbo volume and remove and replace the vent valve with a blank followed be a leak testing of the CFF joints on the Y-mid volume Also, set IP9 to Fixed 7000V -> This leaves only the X-mid still in Step Mode (currently 5000V)