There were issues with attempting to engage the ITMY M0 and R0 damping filters. After investigation, the medm filter values for the *COILOUTF_* gains were inconsistent with earlier changes to these gains. The ITMY M0 and R0 damping filters were last engaged on the LVEA SUS Test Stand with these values just before the BSC8 cartridge install. Damping functionality can be confirmed with a live dataviewer session displaying the signal damping. The values have been changed to the following: ITMY M0 COILOUTF_* 01/03/2012 before 01/03/2012 AFTER F1 = -1 F1 = 1 F2 = 1 F2 = 1 F3 = -1 F3 = -1 LF = 1 LF = -1 RT = -1 RT = 1 SD = 1 SD = -1 -------------------------------------------------- ITMY R0 COILOUTF_* 01/03/2012 before 01/03/2012 AFTER F1 = -1 F1 = 1 F2 = -1 F2 = 1 F3 = 1 F3 = -1 LF = -1 LF = 1 RT = 1 RT = -1 SD = 1 SD = -1