Reports until 17:42, Friday 17 July 2015
H1 GRD
jameson.rollins@LIGO.ORG - posted 17:42, Friday 17 July 2015 - last comment - 00:07, Sunday 19 July 2015(19723)
Guardian core upgraded to point release to address "double main" bug

Guardian core upgraded to fix "double main" execution bug.

I have just installed a new version of Guardian core:

guardian r1449

It address the "double main" execution bug that was been has been plaguing the system.  See guardian bug 879, ECR 1078.

The new version is in place, but none of the guardian nodes have been restarted yet to pull in the new version.

You can either manually restart the nodes with 'guardctrl restart', or just try rebooting the whole guardian machine.  I might start with the former, to just target the important lock acquisition nodes (ISC_LOCK, etc.), and wait until Tuesday maintenance for a full restart of the Guardian system.

Comments related to this report
evan.hall@LIGO.ORG - 00:07, Sunday 19 July 2015 (19735)

ISC_LOCK and ISC_DRMI were restarted around 2015-07-19 07:07:00 Z.