Reports until 14:49, Saturday 18 July 2015
H1 ISC (ISC)
stefan.ballmer@LIGO.ORG - posted 14:49, Saturday 18 July 2015 (19732)
New way for filter module code to permanently break
What I did
- Take a filter that ramps over 3sec (always on)
- edit the foton file top a 1 sec ramp
- start the ramp, but before it finishes - load the new filter.
- The filter module keeps ramping, and never finishes...

- I could reproduce this twice.
- I attached a snap of the still ramping FM1 on LSC-REFLBIAS.

- To fix it, I considered rebooting, but since the I suspected the problem to be a runaway counter, I simply added a filter with 600sec ramp time (long enough to catch the original filter ramp). 10min later (the time it took to write this log) it was fixed...
Images attached to this report