Ops Station alarms

Might be nothing, but the following alarms have been going off continuously for the past few days:

EX HEPI DIFF PRESSURE (yellow)

EX DUST1, EY DUST1 (RED), and LVEA DUST

Comments related to this report
hugh.radkins@LIGO.ORG - 09:17, Monday 20 July 2015 (19755)

The EndX HEPI Pressure Sensors are espectially noisy.  EE promises efforts to quiet them.  Meanwhile I've opened up the alarm levels to +-9psi from setpoint.