Rana, Stefan
Using Rana's filter fitting tool (available in
/ligo/home/rana.adhikari/Templates/DTT/LSC/FF
or
/ligo/home/controls/sballmer/today/FF
we remeasured and fitted the MICH FF transfer function.
The new fitted filter (FF3 in FM4) is
sos(-0.000543835088, [ -1.93662264300273; 0.95485272408082; 0.30546714694311; -0.69453285305689;
-1.99510327713713; 0.99517904131748; -1.99243149865104; 0.99250763632503;
-1.99954772753581; 0.99957826550970; -1.99936615655289; 0.99939939939844;
-1.99965218293192; 0.99975661861859; -1.99993380253468; 1.00003473727562;
-1.99969845455122; 0.99979417820973; -1.99992371170330; 1.00002274176099;
-1.99981093117311; 0.99985759151419; -1.99995617290421; 1.00000284176776;
-1.99985737603421; 0.99996014647150; -1.99984813627844; 0.99995086001340;
-1.99992036795975; 0.99996576562300; -1.99993708678199; 0.99998253575133;
-1.99944212960262; 0.99996998756589; -1.99944272164552; 0.99997065091132;
-1.99975193818562; 0.99999930668374; -1.99975187384463; 0.99999929435542; ],"o")
Plot 1 shows the fit quality,
Plot 2 shows the achieved subtraction, with an artificial MICH drive.