Reports until 08:18, Tuesday 21 July 2015
H1 SUS (CDS)
jeffrey.kissel@LIGO.ORG - posted 08:18, Tuesday 21 July 2015 - last comment - 14:42, Wednesday 22 July 2015(19780)
H1SUSAUXEX and EY Model Change Prep
J. Kissel, B. Weaver

Betsy and I have updated the end-station SUSAUX top-level models to include Stuart's new library block for the HV and LV ESD analog readback monitors, as per WP 5373, ECR E1400232, II 859.
with the changes as described in LHO aLOG 18819, and obeying wiring diagram D1400177 , specifically p11.

They been compiled against RCG 2.9.5, we'll wait for Dave to confirm that we want 2.9.5 or 2.9.6, and will install later in the morning, as per today's schedule (LHO aLOG 19770).
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:26, Tuesday 21 July 2015 (19795)CDS
This models have been installed, compiled against RCG 2.9.5 (given the issues with RCG branch 2.9; see LHO aLOG 19793). All channels appear functional, but now we see that the digital monitor channels that were in the QUAD AUX model (which are white on the AUX overview) are now in the QUAD MASTER model have turned into bits (which are now green / grey and alive); see attached.

@Stuart -- should we remove these white channels from the AUX overview screen?

Note -- the cable for the digital monitoring doesn't yet exist, so the new digital monitor bits are at the moment meaningless.
betsy.weaver@LIGO.ORG - 14:42, Wednesday 22 July 2015 (19843)

h1susaux ex and ey model updates as per the above have been committed to svn.