jeffrey.kissel@LIGO.ORG - posted 15:36, Thursday 05 January 2012 (1981)
All BSC8 Damping Loops are Functional
T. Sadecki, J. Kissel

Travis / Hugh can give more details of the problems had during cabling up the H2SUSFMY, but once we got all BOSEMs turned on, and the OSEMINF filters were fixed, it was trivial to close the damping loops on FMY (as it should be!).

All damping loops (ITMY M0, ITMY R0, and FMY M1) are closed and running.

Watchdog levels:
OSEM DC -- +/- 30000
OSEM AC RMS -- 8000
ACT AC RMS -- 25000

Typical watched levels with damping loops closed (and no one mucking around the chamber)
OSEM DC -- ~15000
OSEM AC RMS -- < 150