The guardian request and state was DOWN when I arrived. I had some trouble with tuning the VCO to manually find the IR resonance in the CHECK_IR state. The wiki instructions said to use the LSC overview screen but should have said the ALS overview screen. Ed has updated them. I think I was also using the wrong slider. I was using the 'Tune Ofs (V)' slider and it was fighting me. I think I was supposed to use the 'Set Off (Hz)' slider. I will confirm this with commissioners and add this to the wiki. It eventually reached DRMI_LOCKED twice. In both instances it lost lock on its way to ENGAGE_ASC. The first time was from PREP_TR_CARM. The second time was from CARM_ON_TR.