Reports until 12:34, Saturday 25 July 2015
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 12:34, Saturday 25 July 2015 (19924)
h1fw1 configuration changed for stability

Now that h1fw0 is stable, we are testing making h1fw1 stable by having it only write commissioning frames and not science frames. This is a temporary fix to support the current commissioning work where reliability is more important than redundency. The frequent restarts of h1fw1 (whose data is served by h1nds1 which is the default NDS) was causing commissioning issues due to data gaps and unavailability. Also note that we have not had any crashes of the framewriter OS or hardware, and so redundency is less of an issue outside of a science run.

After the 12:02 h1fw1 restart today it is now running the new configuration.

The current DAQ configuration is:

frame-writers 

name science frames commissioning frames trends
h1fw0 YES NO YES 
h1fw1 NO YES YES

nds-servers

name serving default NDS
h1nds0 h1fw0 Commissioning frames* NO
h1nds1 h1fw1 Commissioning frames YES

* This is a mistake now that h1fw0 is not writing commissioning frames, needs a restart of h1nds0 to fix which could impact on Guardian nodes, so we are delaying this.