DTT rampdown abort not working?

I was running an ASC OLTF swept-sine template with a request for a 10 s rampdown time.

From the EXCMON of the drive channel, it seems that this rampdown did not happen. Rather, the excitatation continued at full strength for about 10 s and then cut off abruptly.

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 01:42, Sunday 26 July 2015 (19933)

Yes, it appears this feature is broken, at least in swept sine mode.

I pushed the abort button around 06:20:00 Z (around the 10 second mark in the attachment). The excitation continues at full strength until the last second. Then, as far as I can tell, there is some slightly different waveform being written to the excitation channel for about a second. Then the excitation stops abruptly, causing a lockloss.