work tonight
Lisa, Matt,Jenne, Evan, Stefan,Hang, Sheila

None of these things changed the DARM noise.  (just the calibration)

Comments related to this report
evan.hall@LIGO.ORG - 11:59, Wednesday 09 September 2015 (21328)

As a follow-up to point #4: I redid the bias reduction test, this time by reducing the voltage from 380 V to 190 V.

  • 2015-09-09 02:55:00 to 03:00:00: nominal configuration (380 V bias, digital gain -30 ct/ct in EY ESD drivealign)
  • 2015-09-09 03:04:20 to 03:09:20: reduced bias configuration (190 V bias, digital gain -60 ct/ct in EY ESD drivealign)

As before, there was no obvious change in the DARM noise. [See attachment.]