TCS test in progress

Kiwamu, Stefan, Evan

We are trying to minimize the coupling of frequency and intensity noise into DARM by tuning the central heating on the IX CP.

The following excitations have been set up:

The amplitudes were chosen so that each line has an SNR of 50 or so in OMC DCPD sum with a 10 s FFT. Each demodulator demodulates OMC DCPD sum at the appropriate frequency, and then lowpasses I and Q with a 100 mHz, 4th-order butterworth.

At 2015-08-03 01:19:45 Z we changed the IX CP heating power from 0.23 W to 0.36 W.

At 2015-08-03 02:57:25 Z we changed the IX CP heating power from 0.36 W to 0.53 W.

At 2015-08-03 04:26:20 Z we changed the IX CP heating power from 0.53 W to 0.41 W.


Additionally:

Comments related to this report
evan.hall@LIGO.ORG - 21:59, Sunday 02 August 2015 (20154)

Stefan has reverted the rewiring on the CARM board.

We are leaving the injected frequency line on so we can watch it as the interferometer settles into its new thermal state.

stefan.ballmer@LIGO.ORG - 22:42, Sunday 02 August 2015 (20155)
Also, we further increased the ISS gains: the first loop went up by 10dB, the second loop by 6dB. No immediate noise improvement was visible in DARM.
lisa.barsotti@LIGO.ORG - 10:09, Monday 03 August 2015 (20159)ISC
I looked at OMC SUM/NULL during the long lock last night, after the frequency noise injection was turned off.
There is no significant difference between the beginning and the end of the lock. The excess of noise was of the order of 10% shot noise level, similarly to the night before. The highest excess of noise I have seen is ~15%, corresponding to  a few days ago , July 31st.
Images attached to this comment