Displaying report 1-1 of 1.
Reports until 17:26, Monday 03 August 2015
H1 SUS (CAL, ISC)
jeffrey.kissel@LIGO.ORG - posted 17:26, Monday 03 August 2015 (20177)
QUAD Model Prep for New CAL Line, Adding L3_ISCINF_L_IN1 to Science Frames @ 16k, and Adding LP Filters and log10 computation to Violin Monitors
J. Kissel
WP 5405

I've prepped, compiled, and committed changes to the QUAD_MASTER (and FOUROSEM_DAMPED_STAGE_MASTER_WITH_DAMP_MODE) library parts to incorporate the following changes:
1) Added ${IFO}:SUS-${OPTIC}_L3_CAL_LINE oscillator infrastructure for future tracking of the L2-PUM / L3-TST actuation strength ratio.
    ECR E1500329
    Integration Issue 1088

2) Added ${IFO}:SUS-${OPTIC}_L3_ISCINF_L_IN1 to the science frames at 16384 [Hz], as option 2 in 
    ECR E1500323
    Integration Issue 1085

3) Adding low-pass filter banks and log10 processing after the True RMS violin mode monitors as a final implementation.
    ECR E1500271
    Integration Issue 1066

4) Removing all residual, redundant EPICs records storing IPC error rates. I mention them here, but these changes were prepped last Friday (see LHO aLOG 20124).
    ECR E1500230
    Integration Issue 1054

Attached are the relevant screenshots of the changes. 

To absorb the first three of these changes at LLO, one needs only to update the following library parts:
/opt/rtcds/userapps/trunk/sus/common/models/
QUAD_MASTER.mdl
FOUROSEM_DAMPED_STAGE_MASTER_WITH_DAMP_MODE.mdl
Unfortunately, the 4th change requires pruning on every top level model, as described in LHO aLOG 20124.

I'll construct MEDM screens to go with these model changes once they're installed and running.
Images attached to this report
Displaying report 1-1 of 1.