Keita, Kiwamu,
We updated the lists of the sceice frame channels on the LSC, OMC and ASCIMC models. This means that we edited the following master blocks:
asc/common/models/ASCIMC_MASTER.adl
lsc/common/models/lsc.mdl
lsc/common/models/lscimc.mdl
omc/common/models/omc.mdl
omc/common/models/omclsc.mdl
Then we recompiled, reinstalled and restarted the three models. Additionally, burtrestored them back to 10:10 PT of this morning. After we double-checked the ini files to make sure that the right channels were selected, we checked in the above common blocks to the SV
Additionally, we added commissioning frame for the EOM driver signals such as LSC-MOD_RF9_AM_ERR and etc
The followings are lists of the science frame channels after the update. Note that we did not edit ALSEX or ALSEY but they are listed for completeness:
kiwamu.izumi@opsws5:/opt/rtcds/lho/h1/chans/daq$ grep -B 1 "^acquire=3" H1LSC.ini | grep DQ
[H1:IMC-F_OUT_DQ]
[H1:IMC-I_OUT_DQ]
[H1:IMC-L_OUT_DQ]
[H1:IMC-REFL_DC_OUT_DQ]
[H1:IMC-TRANS_OUT_DQ]
[H1:LSC-ASAIR_B_RF90_I_ERR_DQ]
[H1:LSC-MCL_IN1_DQ]
[H1:LSC-MCL_OUT_DQ]
[H1:LSC-MICH_IN1_DQ]
[H1:LSC-MICH_OUT_DQ]
[H1:LSC-ODC_CHANNEL_OUT_DQ]
[H1:LSC-POPAIR_B_RF18_I_ERR_DQ]
[H1:LSC-POPAIR_B_RF90_I_ERR_DQ]
[H1:LSC-POP_A_LF_OUT_DQ]
[H1:LSC-POP_A_RF45_I_ERR_DQ]
[H1:LSC-POP_A_RF45_Q_ERR_DQ]
[H1:LSC-POP_A_RF9_I_ERR_DQ]
[H1:LSC-POP_A_RF9_Q_ERR_DQ]
[H1:LSC-PRCL_IN1_DQ]
[H1:LSC-PRCL_OUT_DQ]
[H1:LSC-REFL_A_LF_OUT_DQ]
[H1:LSC-REFL_A_RF45_I_ERR_DQ]
[H1:LSC-REFL_A_RF45_Q_ERR_DQ]
[H1:LSC-REFL_A_RF9_I_ERR_DQ]
[H1:LSC-REFL_A_RF9_Q_ERR_DQ]
[H1:LSC-REFL_SERVO_ERR_OUT_DQ]
[H1:LSC-REFL_SERVO_SLOW_OUT_DQ]
[H1:LSC-SRCL_IN1_DQ]
[H1:LSC-SRCL_OUT_DQ]
kiwamu.izumi@opsws5:/opt/rtcds/lho/h1/chans/daq$ grep -B 1 "^acquire=3" H1OMC.ini | grep DQ
[H1:LSC-DARM_IN1_DQ]
[H1:LSC-DARM_OUT_DQ]
[H1:LSC-REFL_SERVO_CTRL_OUT_DQ]
[H1:OMC-ASC_ANG_X_OUT_DQ]
[H1:OMC-ASC_ANG_Y_OUT_DQ]
[H1:OMC-ASC_P1_I_OUT_DQ]
[H1:OMC-ASC_P2_I_OUT_DQ]
[H1:OMC-ASC_POS_X_OUT_DQ]
[H1:OMC-ASC_POS_Y_OUT_DQ]
[H1:OMC-ASC_Y1_I_OUT_DQ]
[H1:OMC-ASC_Y2_I_OUT_DQ]
[H1:OMC-DCPD_A_OUT_DQ]
[H1:OMC-DCPD_B_OUT_DQ]
[H1:OMC-DCPD_NULL_OUT_DQ]
[H1:OMC-DCPD_SUM_OUT_DQ]
[H1:OMC-LSC_DITHER_OUT_DQ]
[H1:OMC-LSC_I_OUT_DQ]
[H1:OMC-LSC_SERVO_OUT_DQ]
[H1:OMC-ODC_CHANNEL_OUT_DQ]
[H1:OMC-PZT1_MON_AC_OUT_DQ]
[H1:OMC-PZT1_MON_DC_OUT_DQ]
[H1:OMC-PZT2_MON_AC_OUT_DQ]
[H1:OMC-PZT2_MON_DC_OUT_DQ]
kiwamu.izumi@opsws5:/opt/rtcds/lho/h1/chans/daq$ grep -B 1 "^acquire=3" H1ASCIMC.ini | grep DQ
[H1:IMC-DOF_1_P_IN1_DQ]
[H1:IMC-DOF_1_Y_IN1_DQ]
[H1:IMC-DOF_2_P_IN1_DQ]
[H1:IMC-DOF_2_Y_IN1_DQ]
[H1:IMC-DOF_3_P_IN1_DQ]
[H1:IMC-DOF_3_Y_IN1_DQ]
[H1:IMC-DOF_4_P_IN1_DQ]
[H1:IMC-DOF_4_Y_IN1_DQ]
[H1:IMC-DOF_5_P_IN1_DQ]
[H1:IMC-DOF_5_Y_IN1_DQ]
[H1:IMC-IM4_TRANS_PIT_OUT_DQ]
[H1:IMC-IM4_TRANS_SUM_OUT_DQ]
[H1:IMC-IM4_TRANS_YAW_OUT_DQ]
[H1:IMC-ISS_QPD_PIT_OUT_DQ]
[H1:IMC-ISS_QPD_SUM_IN1_DQ]
[H1:IMC-ISS_QPD_SUM_OUT_DQ]
[H1:IMC-ISS_QPD_YAW_OUT_DQ]
[H1:IMC-MC1_PIT_OUT_DQ]
[H1:IMC-MC1_YAW_OUT_DQ]
[H1:IMC-MC2_PIT_OUT_DQ]
[H1:IMC-MC2_TRANS_PIT_OUT_DQ]
[H1:IMC-MC2_TRANS_SUM_OUT_DQ]
[H1:IMC-MC2_TRANS_YAW_OUT_DQ]
[H1:IMC-MC2_YAW_OUT_DQ]
[H1:IMC-MC3_PIT_OUT_DQ]
[H1:IMC-MC3_YAW_OUT_DQ]
[H1:IMC-ODC_CHANNEL_OUT_DQ]
[H1:IMC-PWR_IN_OUT_DQ]
[H1:IMC-PZT_PIT_OUT_DQ]
[H1:IMC-PZT_YAW_OUT_DQ]
[H1:IMC-WFS_A_DC_PIT_OUT_DQ]
[H1:IMC-WFS_A_DC_SUM_OUT_DQ]
[H1:IMC-WFS_A_DC_YAW_OUT_DQ]
[H1:IMC-WFS_A_I_PIT_OUT_DQ]
[H1:IMC-WFS_A_I_YAW_OUT_DQ]
[H1:IMC-WFS_A_Q_PIT_OUT_DQ]
[H1:IMC-WFS_A_Q_YAW_OUT_DQ]
[H1:IMC-WFS_B_DC_PIT_OUT_DQ]
[H1:IMC-WFS_B_DC_SUM_OUT_DQ]
[H1:IMC-WFS_B_DC_YAW_OUT_DQ]
[H1:IMC-WFS_B_I_PIT_OUT_DQ]
[H1:IMC-WFS_B_I_YAW_OUT_DQ]
[H1:IMC-WFS_B_Q_PIT_OUT_DQ]
[H1:IMC-WFS_B_Q_YAW_OUT_DQ]
kiwamu.izumi@opsws5:/opt/rtcds/lho/h1/chans/daq$ grep -B 1 "^acquire=3" H1ALSEX.ini | grep DQ
[H1:ALS-X_ODC_CHANNEL_OUT_DQ]
[H1:LSC-X_ARM_OUT_DQ]
[H1:LSC-X_TIDAL_OUT_DQ]
kiwamu.izumi@opsws5:/opt/rtcds/lho/h1/chans/daq$ grep -B 1 "^acquire=3" H1ALSEY.ini | grep DQ
[H1:ALS-Y_ODC_CHANNEL_OUT_DQ]
[H1:LSC-Y_ARM_OUT_DQ]
[H1:LSC-Y_TIDAL_OUT_DQ]
LSC, OMC, and ASCIMC were all burt restored to 10:10am this morning.