Displaying report 1-1 of 1.
Reports until 14:44, Tuesday 04 August 2015
H1 SUS (SUS, SYS)
leonid.prokhorov@LIGO.ORG - posted 14:44, Tuesday 04 August 2015 (20211)
OPLEV Charge measurements
Leo, Jeff
Some charge measurements was done on both ETMs.
We found ETMX ESD driver non functional, Betsy fixed it (see 20203)
Measurements results are in attachments. For most quadrants we have the same trend as discussed in 20067
Images attached to this report