Displaying report 1-1 of 1.
Reports until 16:05, Wednesday 05 August 2015
H1 General
hannah.fair@LIGO.ORG - posted 16:05, Wednesday 05 August 2015 (20269)
Broadband Noise Investigation

Hannah, Stefan, Daniel

It was determined that the broadband noise we've been seeing has been caused by the Harmonic Generator (SN 1043-03, DCC S1000798). To see if this was an issue with the unit or if this is the normal operation, we tested the spare. Using an RF frequency of 9 kHz, lowpass filter of 10.7 kHz, we tested all seven outputs and measured the following noise:

 

Voltage V

Noise nV/√Hz

Noise 1/√Hz

9 kHz RF signal

0.380

8

4.2x10-8

2x Output

0.205

23

1.2x10-7

3x Output

0.177

105

5.9x10-7

4x Output

0.404

34

8.4x10-8

5x Output

0.243

55

2.2x10-7

6x Output

0.268

172

6.4x10-7

10x Output

0.337

252

7.5x10-7

15x Output

0.291

197

6.8x10-7

The x5 output is what we're interested in, and the noise seems to be about the same as what we're already seeing. The power supply was also checked to make sure there were no stray signals. 