Displaying report 1-1 of 1.
Reports until 10:00, Thursday 06 August 2015
H1 CAL
jeffrey.kissel@LIGO.ORG - posted 10:00, Thursday 06 August 2015 (20291)
Installation of ER7 Reference Model Values at ESD, PCAL Line Frequencies
J. Kissel, M. Wade

In order to test out the new GDS calibration pipeline infrastructure, Maddie needs for the newly installed EPICs values that represent the DARM loop model reference values at each calibration line to be populated. Since we don't have a new, vetted, model that represents the current interferometer yet, I've installed the ER7 values, which have been precalculated from Maddie. There are some SDF vs. EPICS values that still need sorting since some of the values are very, very small.

Below, I quote the values entered.
For the PCAL Line at 36.7:
H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_REAL -6.6965e-17
H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_IMAG 7.8784e-18
H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_REAL 1.2887e+06
H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_IMAG -193720
H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_REAL 8.9995e+09
H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_IMAG 1.1573e+10
H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_REAL 0.999
H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_IMAG -0.0462

For the DARM line at 37.3:
H1:CAL-CS_TDEP_ESD_LINE1_REF_A_REAL -6.4774e-17
H1:CAL-CS_TDEP_ESD_LINE1_REF_A_IMAG 7.6853e-18
H1:CAL-CS_TDEP_ESD_LINE1_REF_C_REAL 1.288e+06
H1:CAL-CS_TDEP_ESD_LINE1_REF_C_IMAG -196820
H1:CAL-CS_TDEP_ESD_LINE1_REF_D_REAL 9.1216e+09
H1:CAL-CS_TDEP_ESD_LINE1_REF_D_IMAG 1.1789e+10
H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_REAL 0.999
H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_IMAG -0.0469

For the PCAL line at 331.9:
H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_REAL -8.1357e-19
H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_IMAG -3.8605e-21
H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_REAL 373720
H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_IMAG -890150
H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_REAL 7.7692e+10
H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_IMAG -8.0292e+09
H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_REAL 0.9206
H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_IMAG -0.4128

More details to come.

Displaying report 1-1 of 1.