J. Kissel, M. Wade In order to test out the new GDS calibration pipeline infrastructure, Maddie needs for the newly installed EPICs values that represent the DARM loop model reference values at each calibration line to be populated. Since we don't have a new, vetted, model that represents the current interferometer yet, I've installed the ER7 values, which have been precalculated from Maddie. There are some SDF vs. EPICS values that still need sorting since some of the values are very, very small. Below, I quote the values entered. For the PCAL Line at 36.7: H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_REAL -6.6965e-17 H1:CAL-CS_TDEP_PCALY_LINE1_REF_A_IMAG 7.8784e-18 H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_REAL 1.2887e+06 H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_IMAG -193720 H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_REAL 8.9995e+09 H1:CAL-CS_TDEP_PCALY_LINE1_REF_D_IMAG 1.1573e+10 H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_REAL 0.999 H1:CAL-CS_TDEP_PCALY_LINE1_REF_C_NOCAVPOLE_IMAG -0.0462 For the DARM line at 37.3: H1:CAL-CS_TDEP_ESD_LINE1_REF_A_REAL -6.4774e-17 H1:CAL-CS_TDEP_ESD_LINE1_REF_A_IMAG 7.6853e-18 H1:CAL-CS_TDEP_ESD_LINE1_REF_C_REAL 1.288e+06 H1:CAL-CS_TDEP_ESD_LINE1_REF_C_IMAG -196820 H1:CAL-CS_TDEP_ESD_LINE1_REF_D_REAL 9.1216e+09 H1:CAL-CS_TDEP_ESD_LINE1_REF_D_IMAG 1.1789e+10 H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_REAL 0.999 H1:CAL-CS_TDEP_ESD_LINE1_REF_C_NOCAVPOLE_IMAG -0.0469 For the PCAL line at 331.9: H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_REAL -8.1357e-19 H1:CAL-CS_TDEP_PCALY_LINE2_REF_A_IMAG -3.8605e-21 H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_REAL 373720 H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_IMAG -890150 H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_REAL 7.7692e+10 H1:CAL-CS_TDEP_PCALY_LINE2_REF_D_IMAG -8.0292e+09 H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_REAL 0.9206 H1:CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_IMAG -0.4128 More details to come.