ALL TIMES IN UTC
15:00 IFO not locked. Appears we had a couple of Earthquakes in the Tonga and Ecuador area (~5mag).
15:10 Guardian trying to re-lock. Touched ETMY to correct alignment. Locking sequence commencing.
15:20 IFO broke lock at "Noise_Tunings"
15:35 ESD X railed
15:39 Jim Batch to restart broadcast system
15:48 ISC_LOCK set to down (in Jim W's abscence) due to ESD at EX stillbeing railed.
16:00 Ellie into the optics lab
16:00 ESD EX no longer railed
16:04 talked to Jim and Fil at EX to confirm reset of ESD driver.
16:05 ISC_LOCK re-initiated
16:35 Fill into CER to install Cosmic Ray chassis
17:05 Fil out of CER.
17:05 Robert into LVEA to do HF acoustic injections
17:10 6 Kyle and Gerardo to Y-Mid to get/leave equipment
17:20 Robert and Katie out. Lockloss
17:23 Keita and Jenne to LVEA to investigate/turm off ISS noise injection that may have ben left on.
17:30 Keita and Jenne back
17:40 After the most recent lockloss, it seems that EX ESD driver is having trouble turning back on....AND it's railed
17:58 Found a bug in the code. Was able to reset remotely!
18:02 Begin locking sequence
18:02 Nutsinee popping into LVEA to take pictures at TCS X table.
18:08 Nutsinee out
18:31 Richard out on the roof
19:03 Richard back from the roof
19:07 Cheryl going to have a quick look at the exterior of IOT2R cabling.
19:11 Gerardo and Kyle back from the Mid station
20:52 Kyle and Gerardo to MY then MX then Y2-8.
22:55 Kyle and Gerardo back