J. Kissel, J. Betzweiser, D. Barker WP: 5418 ECR: E1500332 II: 1091 I'll put in a more detailed entry describing all the changes once I've finished with the MEDM screen updates, but I've installed an updated CAL-CS front-end model as per all of the documentation mentioned above. This required a DAQ restart, which thankfully was much more successful than is has been in the recent past. I've confirmed that all old CAL model, bare-essentials, functionality is up and running: - Whitening filter recently installed for DELTAL_CTRL has been moved to DELTAL_CTRL_SUM, because the filter bank has changed name - Turned on the newly named DARM_LINE oscillator at 37.3 [Hz], with an amplitude of 0.08 [ct] (I don't think this amplitude is right; I'll confirm the amplitude with Darkhan shortly, it hasn't been aLOGged). - Filled in the new TM_OUTPUT_MTRX to pass through ETMY into DELTAL CTRL. I can see that this functionality has returned, as Evan is able to get the IFO back to some power level, and the DELTAL ASD lies roughly on the reference. Stay tuned for more detail!
JeffK, Darkhan
MEDM screens are undergoing changes to repliate recent front-end model changes (see attached screenshots). The screens are currently in the state at which we can input parameters needed for calibration: C_0, D_0, A_0^{tst}, A_0^{pum}, A_0^{uim}, A_0^{top}, line frequency and amplitude.
Current status of the screens have been committed to SVN (@ r11235). The modification process will continue tomorrow.
We also found a bug in front-end model that need to be fixed (using Im instead of Re part of a quantity, see attachment).