Reports until 21:49, Sunday 09 August 2015
H1 ISC
sheila.dwyer@LIGO.ORG - posted 21:49, Sunday 09 August 2015 (20364)
phasing refl 9 WFS

Jenne, Gabriele, Sheila

After the calibration work and before the Solomon Islands earthquake, we got a chance to try phasing refl 9 WFS.  The first of the attached screenshots show the phase before we started, and the second shows the phases now.  

We tuned them by injecting a line in the mode cleaner length at 11Hz, with the ASC on and 3 Watts of input power.  When we started the signal in I and Q was about equal, when we finished most of the quadrants had a factor of 3-4 more signal in I than Q.  REFL B quadrant 1 was strange, we weren't able to change the amplitude of the line, but the noise in the two quadrants was clearly changing as we rotated the phase.  

We then made a pitch excitation in CHARD and saw about 8 dB more signal in I than Q for both REFL A and B.  

We think these settings should be OK for relocking, because the IFO stayed locked while we were changing them.  We haven't tested this though because of the earthquake.  

Images attached to this report