LSC ODC Saturation Thresholds

Looking at timeseries graphs for photodiaodes from two separate locks (7-28-15 8:00:00 UTC for two hours AND 8-1-15 10:15:00 UTC for two hours) I've tightened up all the saturation thresholds in the LSC ODC.

Channels New Threshholds
POP_A_RF9 21000
POPAIR_A_RF9 27000
POP_A_RF45 5000
POPAIR_A_RF45 5000
REFL_A_RF9 4000
REFLAIR_A_RF9 300
REFL_A_RF45 4000
REFLAIR_A_RF45 350
REFAIR_B_RF27 3500
REFLAIR_B_RF135 350
ASAIR_A_RF45 4500
Comments related to this report
betsy.weaver@LIGO.ORG - 10:57, Tuesday 11 August 2015 (20425)

Updated SDF to reflect these new changes so they will not get lost in future reboots.