Looking at timeseries graphs for photodiaodes from two separate locks (7-28-15 8:00:00 UTC for two hours AND 8-1-15 10:15:00 UTC for two hours) I've tightened up all the saturation thresholds in the LSC ODC.
Channels | New Threshholds |
POP_A_RF9 | 21000 |
POPAIR_A_RF9 | 27000 |
POP_A_RF45 | 5000 |
POPAIR_A_RF45 | 5000 |
REFL_A_RF9 | 4000 |
REFLAIR_A_RF9 | 300 |
REFL_A_RF45 | 4000 |
REFLAIR_A_RF45 | 350 |
REFAIR_B_RF27 | 3500 |
REFLAIR_B_RF135 | 350 |
ASAIR_A_RF45 | 4500 |
Updated SDF to reflect these new changes so they will not get lost in future reboots.