Displaying report 1-1 of 1.
Reports until 04:43, Tuesday 11 August 2015
H1 ISC
evan.hall@LIGO.ORG - posted 04:43, Tuesday 11 August 2015 - last comment - 11:09, Tuesday 11 August 2015(20404)
The 0.43 Hz pitch instability that just won't die

Cheryl, Evan

The 0.43 Hz pitch instability strikes again. I had to turn up the dHard pitch gain from 10 to 20 in order to prevent a runaway. Back into the guardian it goes!

It takes tens of minutes to ring up, and even after tweaking loops, it never exactly rings down (the fuzz in the attached striptool is almost all from this 0.43 Hz feature).

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 05:54, Tuesday 11 August 2015 (20405)

Attached are error and control signals for the arm pitch loops at several different powers: 10.4 W (blue), 15.2 W (yellow), and 19.8 W (green).

Images attached to this comment
richard.mittleman@LIGO.ORG - 06:30, Tuesday 11 August 2015 (20406)

Is it strong enough to show up in the suspension OSEMS?

matthew.evans@LIGO.ORG - 07:41, Tuesday 11 August 2015 (20407)

Are the OPLEVs still on?  They suppress the ASC gain below 1Hz, and might be the cause of instability.

betsy.weaver@LIGO.ORG - 08:06, Tuesday 11 August 2015 (20412)
betsy.weaver@LIGO.ORG - 08:25, Tuesday 11 August 2015 (20415)

A trend of the oplev PIT loop buttons over the last 12 hours show the:

ITMY OL damping OFF

ITMX OL damping ON

SR3 OL damping ON

PR3 OL damping OFF

ETMX OL damping OFF

ETMY OL damping OFF

All above YAW loops OFF.

 

BS OL PIT and YAW damping ON.

sheila.dwyer@LIGO.ORG - 11:09, Tuesday 11 August 2015 (20426)

THe sttached screenshot is from the few minutes before Evan turned up the DHARD PIT gain last night.  You can see that there is an oscillation in the Y arm only, and it seems to be soft.  The same oscillation shows up in MICH but it is much smaller.  

As Betsy pointed out, ITMX oplev damping was on last night, while ITMY oplev damping was on.  Both ITM oplev loops are currently turned on in the INCREASE power state of the ISC_LOCK gaurdian, which still seems to be necessary for stability.  Based on OLG measurements of DHARD, the Oplevs should not impact the stability of DHARD.  However, we haven't been able to get good measurements of CHARD since rephasing the REFL WFS and hopefully getting a reasonable amount of gain from these loops.  (just because of other activities).  

Hopefully we can spend some time on CHARD today, which may shed light on why we need the ITM oplevs and hopefully reduce the large optical gain fluctuations we have. 

Images attached to this comment
Displaying report 1-1 of 1.